Generalinstallationrequirements
ThefollowinggeneralinstallationrequirementsareapplicabletothisSU90delivery.
Topics
Supplypoweronpage32
UninterruptedPowerSupply(UPS)onpage32
Wiringonpage32
Compassdeviationonpage33
Noisesourcesonpage33
Drydockingonpage33
Approvalbyclassicationsocietyonpage33
Supplypower
Thesupplyvoltagetotheequipmentistobekeptwithin±10%oftheinstallation’s
nominalvoltage.Maximumtransientvoltagevariationsonthemainswitchboard’s
bus-barsarenottoexceed-15%to+20%ofthenominalvoltage(exceptunderfault
conditions).
UninterruptedPowerSupply(UPS)
TheSimradSU90system(exceptthehullunit)mustbepoweredusinganUninterrupted
PowerSupply(UPS)withsinewaveoutput.
TheUninterruptedPowerSupplymusthavethecapacitytoindependentlymaintain
powertothesystemforaminimumof10minutes.ThisensuresthattheSU90canbe
switchedoffinacontrolledmannerintheeventofapowerfailure.
Wiring
Allcablesrunningbetweensystemcabinetslocatedindifferentroomsand/orondifferent
decksmustbesupportedandprotectedalongtheirentirelengthsusingconduitsand/or
cabletrays.Notethatthecablesmustnotbeinstalledinthevicinityofhigh-power
suppliesandcables,antennacablesorotherpossiblesourcesofinterference.
Formoredetailedinformationaboutcablesandwiring,refertothebasiccable
requirements.
Relatedtopics
Basiccablerequirementsonpage307
32