EasyManua.ls Logo

Simrad SU90 - Page 247

Simrad SU90
328 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Telegramformats
Format
$PSIMP,D,tt,dd,M,U,S,C,V,Cr,Q,In,SL,NL,G,
Cb,error*chksum<CR><LF>
Formatdescription
1PS=Talkeridentier(mandatory)
2IMP=Telegramidentier
3D=Sentencespecier
4tt=Timeofday
5dd=Currentdate
6M=Measurementtype:
D=Depth
T=Temperature
C=Catch
B=Bottom
N=Nosensor
M=Marker
7U=unit;M,forFfordepthmeasurements,CorFfortemperaturemeasurements
8S=source;number(1,2or3)ofthesensorprovidingthecurrentdatavalues
9C=channel;thenumber(1to30)ofthecommunicationchannelforthecurrent
datasource
10V=value;themagnitudeofthecurrentsensormeasurement
11Cr=changerate;themagnitudeofthecurrentdepthortemperaturemeasurement
12Q=quality:
0=Noconnectionbetweenthesensorandthereceiver
1=Oneortwotelemetrypulsesarelost,currentvalueispredicted
2=Thecurrentdatavalueisreliable
13In=interference:
0=Nointerference
1=Interferencedetected
14SL=signallevelthesignallevelofthetelemetrypulse,measuredindB//1µPa
15NL=noiseleveltheaveragenoiselevelofthecurrentchannel,measuredindB
//1µPa
16G=thecurrentgain;0,20or40dB.
17Cb=cablequality:
0=cableisnotconnected
1=cableisOK
2=ashortcircuit,orthehydrophonecurrentistoolarge
381293/A
245