EasyManua.ls Logo

TECO A510s - Page 112

TECO A510s
519 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4-34
Group 04: External Analog Input and Output Parameters
Code Parameter Name Setting Range Default Unit
Control mode
Attribute
V/F
V/F
+PG
SLV SV
PM
SV
PM
SLV
SLV2
8: Frequency Lower Limit
O O O O
O O O
9: Jump Frequency 4
O O O O
O O O
10: Added to AI1
OOO O
O O O
11: Positive torque limit
XXO O O O X
12: Negative torque limit
X X O O O O X
13: Regenerative
Torque Limit
X X O O O O X
14: Positive / Negative
Torque Limit
X X O O O O X
15: Torque Reference/
Torque Limit (in
Speed Control)
X X X O O X X
16: Torque
Compensation
X X
OO O X X
17: PTC Overheat
Protection
O O O O O O O
04-06
AI2 Signal
Scanning and
Filtering Time
0.00~2.00 0.03 s O O O O O O O
04-07
AI2 Gain
0.0~1000.0 100.0 % O O O O O O O *1
04-08
AI2 Bias
-100.0~100.0 0 % O O O O O O O *1
04-09
~
04-10
Reserved
04-11
AO1 Function
Setting
0: Output Frequency
0 -
O O O O O O O
1: Frequency Command O O O O O O O
2: Output Voltage O O O O O O O
3: DC Voltage O O O O O O O
4: Output Current O O O O O O O
5: Output Power O O O O O O O
6: Motor Speed O O O O O O O
7: Output Power Factor O O O O O O O
8: AI1 Input O O O O O O O
9: AI2 Input O O O O O O O
10: Torque Command X X O O O O X
11: q-axis Current X X O O O O X
12: d-axis Current X X O O O O X
13: Speed Deviation X X X O O X X
14: Reserved
- - - - - - -
15: ASR Output
X O X O O X X
16: Reserved
- - - - - - -
17: q-axis Voltage X X O O O O X
18: d-axis Voltage X X O O O O X
19: Reserved
- - - - - - -
20: Reserved - - - - - - -
21: PID Input O O O O O O O

Table of Contents