00-14 Acceleration time 1
Range 0.1~6000.0 Sec
00-15 Deceleration time 1
Range 0.1~6000.0 Sec
00-16 Acceleration time 2
Range 0.1~6000.0 Sec
00-17 Deceleration time 2
Range 0.1~6000.0 Sec
00-21 Acceleration time 3
Range 0.1~6000.0 Sec
00-22 Deceleration time 3
Range 0.1~6000.0 Sec
00-23 Acceleration time 4
Range 0.1~6000.0 Sec
00-24 Deceleration time 4
Range 0.1~6000.0 Sec
00-25
Switch-Over Frequency of Acceleration and Deceleration Time 1 and Time 4
Range
0.00~599.00 Hz
Acceleration time is the time required to accelerate from 0 to 100% of maximum output frequency.
Deceleration time is the time required to decelerate from 100 to 0% of maximum output frequency.
Motor 1: Maximum frequency is set by parameter 01-02 and Motor 2 Maximum frequency is set by parameter
01-16.
Note: Actual acceleration and deceleration times can be affected by the inverter driven load.
The default values for the acceleration, deceleration times are dependent on the inverter size.
Size
Acceleration / Deceleration
Default Value
200V series 400V series
1~10HP 1~15HP 10s
15~20HP 20~30HP 15s
30~150HP 40~425HP 20s