VA Motion Controller Programming Manual
254
Note
:
The data storage order of
MOTOROLA
and
INTEL
microprocessor is different.
The
INTEL
format is high and low byte array, and the
MOTOROLA
format is low and high byte
array.
The conversion process is completed normally
BUFFER and DST output-output type error
Exceeding the length of the buffer, the number of bytes to be
copied
BUF_CNT is
larger than the number of available bytes of
the buffer
BUFFER
Exceeding the length of the storage area, the number of bytes to be
copied
BUF CN T
exceeds the length of the storage area
This data type is not supported
The length of the byte to be converted does not correspond to the byte
length of the storage area. The former number of bytes must be divisible by the
latter number of bytes.
Conversion of
INTEL/MOTOROLA
failed
The length of the string is not appropriate. For the data type string, it is
necessary to do additional checks.
Storage areAData type error
BUF_OFFS value is incorrect
BUF_CNT
value is incorrect
The buffer is the same as the storage area address
Note : The number of bytes available for buffer BUFFER - starting from
the BUF_OFFS bytes in the buffer to the last word
LD, FBD programming language
Note
: IL, ST
language programming needs to insert variables
IN
and
OUT
or use constants in