VA Motion Controller Programming Manual
487
11.5.17 MC_ReadTappetStatus (read status command
plurality of lifters points)
FB / FC
Explanation
Applicable model
FB
This instruction is used to read the state of a plurality
of points tappets
VEC-VA-MP-005-
MA
Input parameters
name
Features
type of data
Predetermined
area
(Default value)
The timing
of the entry
into force
Execute
(Execute bit)
When the Execute
FALSE to TRUE, the
instruction execution starts
BOOL
TRUE or
FALSE
(FALSE)
CamTable
(Electronic cam No.)
Establishing a main
cam for setting table based
on the relationship of the
cam shaft from
USINT
0 to 31
Exexcute from
FALSE to TRUE
TappetNum1
(Tappet point number)
Tappet set point
number
UINT
(Non-defa
ult)
Exexcute from
FALSE to TRUE
TappetNum2
(Tappet point number)
Tappet set point
number
UINT
(Non-defa
ult)
Exexcute from
FALSE to TRUE
TappetNum3
(Tappet point number)
Tappet set point
number
UINT
(Non-default)
Exexcute from
FALSE to TRUE