EasyManuals Logo

Dell PowerConnect 5324 User Manual

Dell PowerConnect 5324
370 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #49 background imageLoading...
Page #49 background image
Starting and Configuring the Device 49
The IP subnet mask for the network.
The default gateway IP address.
The SNMP community.
Static IP Address and Subnet Mask
An IP address can be configured on any interface, including a VLAN, a LAG, and a physical port.
After entering the configuration command, it is recommended to check if a port was configured
with the IP address by entering the
show ip interface
command.
Important:
If an IP address is configured on a LAG or physical port (ex. g10), that interface is
removed from VLAN 1.
Static Route Configuration
To manage the device from a remote network a static route must be configured, which is an IP
address to where packets are sent when no entries are found in the device tables. The configured IP
address must belong to the same subnet as one of the device IP interfaces.
To configure a static route, enter the command at the system prompt as shown in the following
configuration example where 100.1.1.1 (mask 24) is the specific management station, and
100.1.1.10 is the static route which acts as the default gateway.
Assigning Static IP Addresses on an Inband Interface
NOTE: This example uses the following assumptions:
The IP address to be assigned to the PowerConnect VLAN interface is 192.168.1.123
The IP subnet mask for the network is 255.255.255.0
The IP address of the default route is 192.168.1.1
The read/write SNMP community string is "private"
console> enable
console# configure
console(config)# username admin password dell level 15
console(config)# interface VLAN 1
console (config-if) # ip address 192.168.1.123 /24
console (config-if) # exit
console (config) # ip default-gateway 192.168.1.1
console (config) # snmp-server community private rw
console(config)# exit
console#

Table of Contents

Other manuals for Dell PowerConnect 5324

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell PowerConnect 5324 and is the answer not in the manual?

Dell PowerConnect 5324 Specifications

General IconGeneral
Switching Capacity48 Gbps
VLAN SupportYes
Rack MountableYes
Device TypeSwitch
MAC Address Table Size8K entries
RAM64 MB
Flash Memory8 MB
Power DeviceInternal power supply
Voltage RequiredAC 120/230 V (50/60 Hz)
Jumbo Frame SupportYes
Ports24 x 10/100/1000 + 2 x SFP
ManagementWeb-based, SNMP, CLI
Enclosure TypeRack-mountable
Routing ProtocolStatic IP routing
Remote Management ProtocolSNMP 1, 2, 3
FeaturesFlow control, auto-negotiation, port mirroring, Quality of Service (QoS)
Compliant StandardsIEEE 802.3, IEEE 802.3u, IEEE 802.3ab, IEEE 802.3x
Operating Temperature0 °C to 45 °C
Storage Temperature-20 °C to 70 °C
Humidity5% to 95% (non-condensing)
LayerLayer 2