Configuring System Information 91
Information received from SNTP servers is evaluated based on the Time level and server type.
SNTP time definitions are assessed and determined by the following time levels:
T1
— The time at which the original request was sent by the client.
T2
— The time at which the original request was received by the server.
T3
— The time at which the server sent the client a reply.
T4
— The time at which the client received the server's reply.
Polling for Unicast Time Information
Polling for Unicast information is used for polling a server for which the IP address is known. T1 -
T4 are used to determine the server time. This is the preferred method for synchronizing switch
time.
Polling for Anycast Time Information
Polling for Anycast information is used when the server IP address is unknown. The first anycast
server to return a response is used to set the time value. Time levels T3 and T4 are used to
determine the server time. Using Anycast time information for synchronizing switch time is
preferred to using Broadcast time information.
Broadcast Time Information
Broadcast information is used when the server IP address is unknown. When a broadcast message is
sent from an SNTP server, the SNTP client listens for the response. The SNTP client neither sends
time information requests nor receives responses from the Broadcast server.
MD5 (Message Digest 5) Authentication safeguards switch synchronization paths to SNTP servers.
MD5 is an algorithm that produces a 128-bit hash. MD5 is a variation of MD4, and increases MD4
security. MD5 verifies the integrity of the communication, authenticates the origin of the
communication.
Click
System
SNTP
in the tree view to open the
SNTP
page.

Table of Contents

Other manuals for Dell PowerConnect 5324

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell PowerConnect 5324 and is the answer not in the manual?

Dell PowerConnect 5324 Specifications

General IconGeneral
Switching Capacity48 Gbps
VLAN SupportYes
Rack MountableYes
Device TypeSwitch
MAC Address Table Size8K entries
RAM64 MB
Flash Memory8 MB
Power DeviceInternal power supply
Voltage RequiredAC 120/230 V (50/60 Hz)
Jumbo Frame SupportYes
Ports24 x 10/100/1000 + 2 x SFP
ManagementWeb-based, SNMP, CLI
Enclosure TypeRack-mountable
Routing ProtocolStatic IP routing
Remote Management ProtocolSNMP 1, 2, 3
FeaturesFlow control, auto-negotiation, port mirroring, Quality of Service (QoS)
Compliant StandardsIEEE 802.3, IEEE 802.3u, IEEE 802.3ab, IEEE 802.3x
Operating Temperature0 °C to 45 °C
Storage Temperature-20 °C to 70 °C
Humidity5% to 95% (non-condensing)
LayerLayer 2