Operation Manual - System Management
Quidway S3500 Series Ethernet Switches Chapter 7 NTP Configuration
Huawei Technologies Proprietary
7-17
# Set Quidway1 as time server.
[Quidway2[ ntp-service unicast-server 1.0.1.11
# Enable authentication.
[Quidway2] ntp-service authentication enable
# Set the key.
[Quidway2] ntp-service authentication-keyid 42 authentication-mode md5 aNiceKey
# Set the key as reliable.
[Quidway2] ntp-service reliable authentication-keyid 42
[Qudiway2] ntp-service unicast-server 1.0.1.11 authentication-keyid 42
The above examples synchronized Quidway2 by Quidway1. Since Quidway1 has not
been enabled authentication, it cannot synchronize Quidway2. And now let us do the
following additional configurations on Quidway1 :
# Enable authentication.
[Quidway1] ntp-service authentication enable
# Set the key.
[Quidway1] ntp-service authentication-keyid 42 authentication-mode md5 aNiceKey
# Configure the key as reliable.
[Quidway1] ntp-service reliable authentication-keyid 42