Sample Output
For M5, M10, M20, and M40 routers:
user@host> show chassis environment
Class Item Status Measurement
[...Output truncated...]
Misc Craft Interface OK
For M40e and M160 routers:
user@host> show chassis environment
Class Item Status Measurement
[...Output truncated...]
FPM CMB OK 32 degrees C / 89 degrees F
FPM Display OK 32 degrees C / 89 degrees F
[...Output truncated...]
For M40e and M160 routers:
user@host> show chassis environment
Class Item Status Measurement
[...Output truncated...]
FPM GBUS OK 28 degrees C / 82 degrees F
FPM Display OK 31 degrees C / 87 degrees F
[...Output truncated...]
Meaning For M5, M10, M20, and M40 routers, the command output displays the craft interface
state, which can be OK or Absent.
For M40e and M160 routers, the command output displays the FPM Chassis Management
Bus (CMB) status and the FPM display status, which can be OK or Absent.
For M320 routers, the command output displays the FPM CMB status only.
For T320 routers and T640 routers, the command output displays the FPM circuitry and
the FPM display status, which can be OK or Absent.
(For M40e, M160, M320, and T320, T640, T1600, and TX Matrix routers) To monitor the
craft interface environmental status, use the following command:
user@host> show chassis environment fpm
user@host> show chassis environment fpm
FPM status:
State Online
FPM CMB Voltage:
5.0 V bias 5030 mV
8.0 V bias 8083 mV
FPM Display Voltage:
5.0 V bias 4998 mV
FPM CMB temperature 34 degrees C / 93 degrees F
FPM Display temperature 35 degrees C / 95 degrees F
CMB Revision 12
The command output displays the status of the FPM or craft interface, which can be
Online or Offline. It also displays information about the power supplied to the FPM CMB
or FPM GBUS, information about the FPM display power supply, the temperature of the
257Copyright © 2012, Juniper Networks, Inc.
Chapter 9: Monitoring the Craft Interface

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Juniper M Series and is the answer not in the manual?

Juniper M Series Specifications

General IconGeneral
BrandJuniper
ModelM Series
CategoryNetwork Router
LanguageEnglish

Related product manuals