For the M40e, M120, M160, M320, T320, T640, T1600, TX Matrix, and TX Matrix Plus
routers, to display the power supply status, use the following command:
user@host> show chassis environment pem
PEM 0 status:
State Online
Temperature OK
DC input OK
DC output OK
Load Less than 20 percent
Voltage:
48.0 V input 69028 mV
48.0 V fan supply 48839 mV
5.0 V bias 5013 mV
8.0 V bias 8253 mV
PEM 1 status:
State Online
Temperature OK
DC input OK
DC output OK
Load Less than 20 percent
Voltage:
48.0 V input 69307 mV
48.0 V fan supply 49170 mV
5.0 V bias 4991 mV
8.0 V bias 8263 mV
For each PEM, the command output displays the slot number, status, temperature, DC
input and output, load percentage, and voltage. You can display the status of a particular
power supply by specifying the slot number.
For T320, T640, T1600, TX Matrix, and TX Matrix Plus routers, the command output
displays the PEM slot number, status, temperature, DC input status, and DC output for
each Flexible PIC Concentrator (FPC), SONET Clock Generator (SCG), Control Board,
and Switch Interface Board (SIB). You can display the status of a particular power supply
by specifying the slot number.
user@host> show chassis environment pem
PEM 1 status:
State Online
Temperature 33 degrees C / 91 degrees F
DC input: OK
DC Output: Voltage Current Power Load
FPC 0 53783 3368 181 24
FPC 1 0 0 0 0
FPC 2 0 0 0 0
FPC 3 0 0 0 0
FPC 4 54041 3462 187 24
FPC 5 53883 5187 279 37
FPC 6 0 0 0 0
FPC 7 0 0 0 0
SCG/CB/SIB 54066 4031 217 18
Check the Power Supply LEDs
Purpose To check the power supply status by looking at the LEDs on the faceplate.