Action To display power supply error messages in the chassisd log file, use the following
command:
user@host> show log chassisd | match pem
Sample Output
user@host> show log chassisd | match pem
Jul 15 11:18:59 CMB cmd to PEM#0 [0xf8], Amber LED Off [0x18]
Jul 15 11:18:59 PEM#0 - Amber LED Off
Jul 15 11:18:59 CMB cmd to PEM#0 [0xf8], Green LED Off [0x1a]
Jul 15 11:18:59 PEM#0 - Green LED Off
Jul 15 11:18:59 CMB cmd to PEM#0 [0xf8], Blue LED Off [0x16]
Jul 15 11:18:59 PEM#0 - Blue LED Off
Jul 15 11:18:59 CMB cmd to PEM#1 [0xf9], Amber LED Off [0x18]
Jul 15 11:18:59 PEM#1 - Amber LED Off
Jul 15 11:18:59 CMB cmd to PEM#1 [0xf9], Green LED Off [0x1a]
Jul 15 11:18:59 PEM#1 - Green LED Off
Jul 15 11:18:59 CMB cmd to PEM#1 [0xf9], Blue LED Off [0x16]
Jul 15 11:18:59 PEM#1 - Blue LED Off
Jul 15 11:19:02 PEM#0 added
Jul 15 11:19:02 reading PEM 0 initial state
Jul 15 11:19:02 PEM#1 added
Jul 15 11:19:02 reading PEM 1 initial state
Jul 15 11:19:18 CHASSISD_PEM_INPUT_BAD: PEM 1 - INPUT FAIL, status bits: 0xf2,
check breaker
Jul 15 11:19:18 CHASSISD_SNMP_TRAP: SNMP trap: FRU failure: jnxFruContentsIndex
2, jnxFruL1Index 2, jnxFruL2Index 0, jnxFruL3Index 0, jnxFruName PEM 1, jnxFruType
7, jnxFruSlot 2, jnxFruOfflineReason 2, jnxFruLastPowerOff 0, jnxFruLastPowerOn
26221491, jnxFruPowerUpTime 1484
Jul 15 11:19:23 CHASSISD_PEM_INPUT_BAD: PEM 1 - INPUT FAIL, status bits: 0xf2,
check breaker
Jul 15 11:19:28 CHASSISD_PEM_INPUT_BAD: PEM 1 - INPUT FAIL, status bits: 0xf2,
check breaker
Jul 15 11:19:33 CHASSISD_PEM_INPUT_BAD: PEM 1 - INPUT FAIL, status bits: 0xf2,
check breaker
Jul 15 11:19:38 CHASSISD_PEM_INPUT_BAD: PEM 1 - INPUT FAIL, status bits: 0xf2,
check breaker
Meaning The chassisd database provides the date, time, and a component status message. The
chassisd database is dynamic. It is initialized at router startup and is updated when
components are added or removed.
Related
Documentation
Power Supplies Overview on page 275•
Verifying Power Supply Failure
To verify a power supply failure:
1.
Check the Power Supply Power Switch on page 306
2.
Check the Circuit Breaker on page 306
3.
Perform a Power Supply Swap Test on page 306
305Copyright © 2012, Juniper Networks, Inc.
Chapter 10: Monitoring Power Supplies

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Juniper M Series and is the answer not in the manual?

Juniper M Series Specifications

General IconGeneral
BrandJuniper
ModelM Series
CategoryNetwork Router
LanguageEnglish

Related product manuals