EasyManua.ls Logo

Juniper M Series - Figure 131: M40 E Router Power Supplies

Juniper M Series
812 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
NOTE: Mixing AC and DC power supplies is not supported and prevents the
router from booting. If two power supplies are installed, they must be either
both AC or both DC.
A circuit breaker box must be installed on a DC-powered router, while a
circuit breaker is incorporated into each AC power supply. Converting the
router from AC to DC power or vice versa involves removing or installing
the circuit breaker box. Only authorized service personnel should perform
the conversion; this manual does not include instructions.
When two power supplies are installed, at least one Routing Engine and
one FPC must also be installed for both power supplies to power on. In the
absence of this minimum load, only one power supply starts. (The router
powers on and operates correctly with one power supply, but without the
redundancy benefit of having a second power supply installed.)
Figure 131: M40e Router Power Supplies
Related
Documentation
Checklist for Monitoring Power Supplies on page 273
Copyright © 2012, Juniper Networks, Inc.282