SPP temperature 36 degrees C / 96 degrees F
SPR temperature 45 degrees C / 113 degrees F
SPP Power:
1.5 V 1501 mV
2.5 V 2485 mV
3.3 V 3291 mV
5.0 V 5020 mV
5.0 V bias 4974 mV
SPR Power:
1.5 V 1501 mV
2.5 V 2492 mV
3.3 V 3301 mV
5.0 V 5028 mV
5.0 V bias 4986 mV
8.0 V bias 8305 mV
CMB Revision 12
SFM 1 status:
[...Output truncated...]
SFM 2 status:
[...Output truncated...]
SFM 3 status:
gm State Offline
- Hard FPC error
[...Output truncated...]
The command output displays the SFM slot, status, and temperature of the air flowing
past the SPP card and the SPR card. It also displays information about the SFM power
supplies. The chassis management bus (CMB) backup revision level is also displayed.
You can display the environmental status of a particular SFM with the following command:
user@host> show chassis environment sfm sfm-slot
Related
Documentation
Checklist for Monitoring the SFMs on page 441•
Display SFM Alarms
To display SFM alarms and error messages:
1.
Display Current SFM Alarms on page 447
2.
Display SFM Error Messages in the System Log File on page 448
3.
Display SFM Error Messages in the Chassis Daemon Log File on page 448
Display Current SFM Alarms
Purpose To determine the details of the current SFM alarms.
Action To display the current SFM alarms, use the following command:
user@host> show chassis alarms
Sample Output
user@host> show chassis alarms
447Copyright © 2012, Juniper Networks, Inc.
Chapter 18: Monitoring the SFMs