10. Align the rear of the CFEB with the guides inside the chassis and slide it in completely.
11. Press the ejector lever at each end of the CFEB inward.
Do not stack CFEBs on top of or under other components. Place each one individually in
an electrostatic bag or on its own antistatic mat on a flat, stable surface.
Related
Documentation
Checklist for Monitoring the CFEB on page 517•
Obtain CFEB Hardware Information
To display CFEB hardware information:
1.
Display the CFEB Hardware Information on page 529
2.
Display the CFEB Firmware Information on page 529
3.
Locate the CFEB Serial Number ID Label on page 530
Display the CFEB Hardware Information
Purpose To obtain the CFEB hardware information.
Action To display the CFEB hardware information, use the following command:
user@host> show chassis hardware
Sample Output
user@host> show chassis hardware
Hardware inventory:
Item Version Part number Serial number Description
Chassis 30512 M7i
Midplane REV 04 710-008761 CB9213 M7i Midplane
Power Supply 0 Rev 02 740-008985 QB12884 DC Power Supply
Routing Engine REV 09 740-009459 1000482742 RE-5.0
CFEB REV 04 750-010112 CB8664 Internet Processor II
FPC 0 E-FPC
FPC 1 E-FPC
PIC 2 BUILTIN BUILTIN 1x Tunnel
PIC 3 REV 04 750-009099 CB9103 1x G/E, 1000 BASE
Meaning The command output displays the CFEB version level, part number, serial number, and
description.
Display the CFEB Firmware Information
Purpose To display the firmware information running on the CFEB.
Action To display the firmware running on the CFEB, use the following command:
user@host> show chassis firmware
529Copyright © 2012, Juniper Networks, Inc.