Loading...
CHAPTER 40
Monitoring Redundant HCMs
Checklist for Monitoring Redundant HCMs on page 735
Redundant HCMs Overview on page 736
Display Redundant HCM Hardware Information on page 737
Display HCM Status and Mastership on page 737
Switch HCM Mastership on page 738
Display HCM Alarms on page 740
Verify HCM Failure on page 740
Checklist for Monitoring Redundant HCMs
Purpose You monitor redundant High-Availability Chassis Managers (HCMs) on the M10i router
so they can work with a companion Routing Engine to provide control and monitoring
functions for router components. The HCMs also display alarm status and take PICs
online and offline.
Table 161 on page 735 provides a checklist of tasks for you to perform to monitor redundant
HCMs.
Action Table 161: Checklist for Monitoring Redundant HCMs
Command or ActionMonitor Redundant HCM Tasks
“Display Redundant HCM Hardware Information” on page 737
show chassis hardware
“Display HCM Status and Mastership” on
page 737
Look at the LEDs on the HCM faceplate. The
master HCM LED light flashes blue.
1. Check the HCM LEDs on page 737
show chassis environment hcm2. Check the HCM Environmental Status on
page 738
request chassis routing-engine master switch
“Switch HCM Mastership” on page 738
show chassis alarms
“Display HCM Alarms” on page 740
735Copyright © 2012, Juniper Networks, Inc.