SFM 0 SPR REV 05 710-002189 AF1847 Internet Processor II
SFM 1 SPP REV 07 710-001228 BE0175
SFM 1 SPR REV 05 710-002189 BE0201 Internet Processor II
For M160 routers:
user@host> show chassis hardware
Item Version Part number Serial number Description
Chassis 20079 M160
[...Output truncated...]
SFM 0 SPP REV 04 710-001228 AA2860
SFM 0 SPR REV 01 710-001224 AB0139 Internet Processor I
SFM 1 SPP REV 04 710-001228 AA2859
SFM 1 SPR REV 02 710-001224 AA9861 Internet Processor I
SFM 2 SPP REV 06 710-001228 AB3082
SFM 2 SPR
SFM 3 SPP REV 04 710-001228 AA1998
SFM 3 SPR REV 01 710-001224 AB0137 Internet Processor I
[...Output truncated...]
Meaning The command output displays the SFM slot number and SFM serial component (SPP
and SPR) card names, and the SFM revision level, part number, serial number, and
description.
Related
Documentation
Monitoring Redundant SFMs on page 683•
Monitor Redundant SFM Status
To monitor the SFM status:
1.
Display the SFM Summary Status on page 688
2.
Display the SFM LED Status at the Command Line on page 690
3.
Check the SFM LED Status on the Faceplate on page 691
4.
Display the SFM Environmental Status on page 691
Display the SFM Summary Status
Purpose To obtain information about the SFM summary.
Action To display the SFM summary status, use the following command:
user@host> show chassis sfm
Sample Output
For M40e routers:
user@host> show chassis sfm
Temp CPU Utilization (%) Memory Utilization (%)
Slot State (C) Total Interrupt DRAM (MB) Heap Buffer
0 Online 37 3 0 64 16 46
1 Online - Standby 41 3 0 64 16 46
For M160 routers:
Copyright © 2012, Juniper Networks, Inc.688