Table 121: Checklist for Monitoring the CIP (continued)
Command or ActionTasks for Monitoring the CIP
1. Connect to the Ethernet port.
2. Check the LINK LED.
3. Run the Junos OS CLI.
2. Check the Ethernet Port Functionality on
page 485
1. Power down the router.
2. Remove the CIP.
3. Replace the CIP with one that you know works.
4. Power on the router.
3. Perform a CIP Swap Test on page 485
“Get CIP Hardware Information” on page 486
show chassis hardware1. Display CIP Hardware Information on
page 486
Look on the top of the left side of the CIP.2. Locating the CIP Serial Number ID Label
on page 487
Power down the router. To replace and return a
CIP, follow the instructions in the M40e or M160
router hardware guide.
“Replace the CIP” on page 487
Related
Documentation
CIP Overview on page 480•
CIP Overview
Inspect the CIP to ensure connection to the Routing Engines, BITS interfaces for the MCS,
and alarm relay contacts.
The CIP provides an interface through which you can connect to the M40e and M160
Routing Engines, BITS interfaces for the MCS, and alarm relay contacts (see Figure 255
on page 481).
Copyright © 2012, Juniper Networks, Inc.480
M Series and T Series Routers Monitoring and Troubleshooting Guide