Power PEM 0 OK
PEM 1 OK
Temp [...Output truncated...]
SPP 0 OK 37 degrees C / 98 degrees F
SPR 0 OK 46 degrees C / 114 degrees F
SPP 1 OK 38 degrees C / 100 degrees F
SPR 1 OK 48 degrees C / 118 degrees F
SPP 2 OK 39 degrees C / 102 degrees F
SPR 2 OK 54 degrees C / 129 degrees F
SFM 3 Offline
[...Output truncated...]
Meaning The command output displays the status and temperature for the SFM and its two
serialized components: the SPP and SPR cards.
If there is a problem with the SFM status, you can display more detailed environmental
information with the following command:
user@host> show chassis environment sfm
For M40e routers:
SFM 0 status:
State Online
SPP temperature 37 degrees C / 98 degrees F
SPR temperature 41 degrees C / 105 degrees F
SPP Power:
1.5 V 1501 mV
2.5 V 2495 mV
3.3 V 3293 mV
5.0 V 5042 mV
5.0 V bias 4998 mV
SPR Power:
1.5 V 1504 mV
2.5 V 2499 mV
3.3 V 3297 mV
5.0 V 5050 mV
5.0 V bias 5008 mV
8.0 V bias 8288 mV
CMB Revision 12
SFM 1 status:
State Online - Standby
SPP temperature 41 degrees C / 105 degrees F
SPR temperature 40 degrees C / 104 degrees F
SPP Power:
1.5 V 1498 mV
2.5 V 2468 mV
3.3 V 3296 mV
5.0 V 5042 mV
5.0 V bias 4993 mV
SPR Power:
1.5 V 1496 mV
2.5 V 2471 mV
3.3 V 3299 mV
5.0 V 5037 mV
5.0 V bias 4996 mV
8.0 V bias 8266 mV
CMB Revision 12
For M160 routers:
Copyright © 2012, Juniper Networks, Inc.692
M Series and T Series Routers Monitoring and Troubleshooting Guide

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Juniper M Series and is the answer not in the manual?

Juniper M Series Specifications

General IconGeneral
BrandJuniper
ModelM Series
CategoryNetwork Router
LanguageEnglish

Related product manuals