Sample Output
user@host> show log chassisd | match PCG
Aug 27 15:20:51 PCG 0 power verified on in 16 ms
Aug 27 15:20:52 reading PCG 0 initial state
Aug 27 15:20:52 CMB readback PCG 0 [0xe2, 0xff] -> 0xc
Aug 27 15:20:52 reading PCG 0 ideeprom
Aug 27 15:20:52 CMB cmd to PCG 0 [0xe2], Green LED On [0x1b]
Aug 27 15:20:52 PCG 0 - Green LED On
Aug 27 15:20:52 PCG 0 clear alarm 0x3
Aug 27 15:20:52 alarm op fru 1 op 0 reason 3
Aug 27 15:20:52 send: yellow alarm clear, class 100 obj 110 reason 3.
Meaning The chassisd database provides the date, time, and a component status message. The
chassisd database is dynamic. It is initialized at router startup and is updated when
components are added or removed.
Related
Documentation
Checklist for Monitoring Redundant PCGs on page 703
713Copyright © 2012, Juniper Networks, Inc.
Chapter 37: Monitoring Redundant PCGs