EasyManuals Logo
Home>Juniper>Network Router>M Series

Juniper M Series User Manual

Juniper M Series
812 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #785 background imageLoading...
Page #785 background image
Current state Master
Election priority Backup (default)
Temperature 33 degrees C / 91 degrees F
CPU temperature 29 degrees C / 84 degrees F
DRAM 2048 MB
Memory utilization 12 percent
CPU utilization:
User 0 percent
Background 0 percent
Kernel 3 percent
Interrupt 0 percent
Idle 97 percent
Model RE-3.0
Serial ID P10865701255
Start time 2005-02-03 03:13:39 UTC
Uptime 13 days, 21 hours, 12 minutes, 35 seconds
Load averages: 1 minute 5 minute 15 minute
0.00 0.03 0.01
Sample output
user@host> show chassis environment hcm
HCM 0 status:
State Offline
FPGA Revision 27
HCM 1 status:
State Online Master
FPGA Revision 27
Meaning The Routing Engine in slot RE0 and companion HCM in slot HCM0 are backup. The Routing
Engine in slot RE1 and companion HCM in slot HCM1 are master.
To verify an HCM failure, you can also use the following command:
user@host>show chassis environment hcm
The HCM in slot HCM0 is offline. The HCM in slot HCM1 has taken over as master.
Related
Documentation
• Checklist for Monitoring Redundant HCMs on page 735
741Copyright © 2012, Juniper Networks, Inc.
Chapter 40: Monitoring Redundant HCMs

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Juniper M Series and is the answer not in the manual?

Juniper M Series Specifications

General IconGeneral
BrandJuniper
ModelM Series
CategoryNetwork Router
LanguageEnglish

Related product manuals