PARAMETER SETTING AND OPERATION OF PULSE/ANALOG INPUT
7-5 Torque Control
In torque control, a specified torque is applied on the servo motor by inputting an analog voltage-based torque command
into the servo amplifier.
Rotation direction is switched through "Forward selection (RS1)" input/"Reversal selection (RS2)" input.
In torque control, the torque command can be adjusted with torque command soft start used for smoothing torque
command or with the gain settings/filter settings/offset adjustment of analog torque input.
Also a speed limit can be applied on.
■ Pin assignment and wiring
For torque control mode, the following wiring diagram can be used.
Wiring is different when using power supplies of AC 100V,
single-phase AC 200V and DC200V. Please see
"Wiring
the Main Circuit/Control Circuit and Motor Power Supply
Connector", page 4-7
.
*1 When an external regenerative resistor is used, the same is connected between B1/ -B2. SV-075P2/100P2/
150P2/200P2/300P2/500P2 has a built-in regenerative resistor. B2 and B3 are short-circuited. The wire
between B2 and B3 should be disconnected before the external regenerative resistor is connected.
*2 These are short-circuited when delivered. No polarity needs to be considered when connecting a DC reactor.
*3 The AC100V type servo amplifier has no L3/ 1/ 2 terminals.
*4
The differential line driver is equivalent to AM26C31.
*5 SG (signal groud) is short-circuited internally.
For wiring and I/O terminal specification, see "4-5 Wiring I/O Signals", Page 4-24.
NFB No fuse breakeer
MC Magnetic contactor
SA Surge absorber (surge killer)
M Motor
ENC Encoder
RA Alarm output relay
FIL Noise filter
COM1
-
VLM
SG
ALARM
COM0
A+
ˉ
SVON
ˉ
RS2
ˉ
ˉ
SPD2
FSTOP
V-REF
SG
T-REF
A
-
Z+
B
-
ˉ
SEN
ZSP
RS1
RDY
B+
NTL
ZOC
SG
Z
-
RESET
PTL
LSN
LSP
ˉ
ˉ
SPD1
I/O connector
Analog torque command
Signal ground *5
Analog speed limit
Unused
Unused
Unused
Unused
Signal ground *5
Operation ready
Encoder pulse Z phase +
CW selection
Absolute position data request
Servo ON
Encoder pulse B phase -
Encoder pulse Z phase -
Limit switch negative
Alarm reset
Zero speed detection
CCW selection
Limit switch positive
Output common
Unused
Encoder pulse Z phase open collector
Signal ground *5
Encoder pulse A phase +
Negative torque limit selection
Speed selection 1
Encoder pulse A phase -
Encoder pulse B phase +
Warning
Speed selection 2
Unused
Forced stop
Limiting speed
Positive torque limit selection
Unused
Unused
Input common
NFB
Servo motor
*1
Emergency
stop
MC
SA
*2
MC
Analog
monitor
connector
Protective ground terminal
AC 200V type servo amplifier
T
FIL
R
S
Main circuit/
controlcircuit
power supply
connector
*3
Lithium battery with battery housing
+
-
Battery
connector
TMON
SG
2
4
PC
USB
connector
Measuring instrument
VTG
SG
1
3
V
W
Encoder
connector
Motor power
supply
connector
U
M
ENC
MC
Main
circuit
ON
3
4
5
6
7
8
10
11
14
15
16
17
18
19
20
21
22
23
*4
Main
circuit
OFF
RA
B2
B3
L2
L1C
L3
L2C
L1
B1/
+
-
1
-
2
RA
24V
24V
24V
26
27
28
29
30
31
32
33
34
35
38
39
41
42
43
44
45
46
24
25