A-78
- SV Series User’s Manual -
APPENDIX
A-6 Motorless Trial Run
SV series can simulate the running of servo motor without running the servo motor to check the readiness of higher-
level equipment and peripheral equipment, allowing wiring, parameters, and system to be verified.
You can do this without running the servo motor.
In the Motor less test, regenerative operation and dynamic braking can't be verified.
Parameter setting
While performing motor less test, the following parameters need to be set up.
*1 If the servo motor is connected, the encoder model used by the servo motor is preferred.
Note
Parameter
type
Category
Level Parameter name Setting range
Setting
unit
factory
setting
Enable
timing
OTH_23
Other Special
*Motorless Trial Run
0: Disable
1: Enable
-0
When power
is ON again
OTH_24
*Motor less test
Motor less encoder
type
*1
0: INC
1: ABS
-0

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keyence SV Series and is the answer not in the manual?

Keyence SV Series Specifications

General IconGeneral
DisplayLCD
Output TypeDigital, Analog
Power Supply24V DC
CommunicationEthernet, RS-232, RS-485
SeriesSV Series
Programming LanguageLadder Logic
MountingPanel mounting
Operating Temperature0 to +50°C
Storage Temperature-20 to +60°C
Vibration Resistance10 to 55 Hz
Shock Resistance30G