7-4 Speed Control
- SV Series User’s Manual -
PARAMETER SETTING AND OPERATION OF PULSE/ANALOG INPUT
7
Torque Limit Setting
A torque limit can be applied on servo motor by inputting an analog voltage signal or internal torque limit signal into
the servo amplifier.
For the setting, see "5-2 Common Function Setting", Page 5-4.
Speed Match Signal Setting
The "Speed match (VCMP)" signal is output when the difference between servo motor speed and command speed is
within the "Speed match range" (VEL_04).
For the setting, see "5-2 Common Function Setting", Page 5-4.
Zero Clamp Signal Setting
The "Zero clamp (ZCLAMP)" signal is ON when the command speed (V-REF/internal speed command 1 to 7) is lower
than the zero clamp speed (VEL_14) and the servo is locked to disable speed command.
For the setting, see "5-2 Common Function Setting", Page 5-4.