3-2 Maintenance, Service and Inspection
Inspection of Servo Amplifier
No routine inspection is required, but for the following items, inspection must be performed at least one time per year.
Life Cycle of Servo Amplifier Components
The expected life of components is shown as follows.
For matters about repairing, please contact the nearest sales agent (on the back cover of this manual).
* The expected life is a reference value. It depends on ambient conditions and application methods.
Inspection of Servo Motor
No routine inspection is required, but for the following items, inspection must be performed at least one time per year.
Life Cycle of Servo Motor Components
The expected life of components is shown as follows:
For matters about repairing, please contact the nearest sales agent (on the back cover of this manual).
* The expected life is a reference value. It depends on mbient conditions and application methods.
Inspecting item
Inspecting time Inspecting contents Measures
Visual check
At least one time
per year
To check whether dirt, dust or oil etc. is
adhered.
To clean with air or a piece of cloth.
Loose screws
To check whether installing screws on terminal
blocks and connectors are loose.
To fasten the loose screws.
Component
Expected
life
Notes
Cooling fan 4 to 5 years
Operating rate: 20 hours/day (used under the condition of
80% rated load and average temperature of 30°C)
Capacitor of main circuit 7 to 8 years
Fuse 10 years
Electrolytic capacitor 5 years
Relay
0.1 million times
ON/OFF circuit of relay contact
Consumables
Expected
life
Notes
Lithium battery with battery case (SV-B1)
Replaceable lithium battery (OP-51422)
20000 hours
Ambient temperature of battery life under the condition of
power OFF and 25°C
Inspecting item Inspecting time Inspecting content Measures
Vibration and sound
check
Daily To check with feeling and hearing.
Please contact the nearest sales
agent.
Visual check
Depending on conditions
of dirt and damage
To lean with a piece of cloth or
compressed air.
-
Measure insulation
resistor
At least one time per
year
To measure the insulation resistance
with a 500V megohmmeter by
disconnecting from servo amplifier.
It is normal if the insulation resistance
exceeds 10M
Ω
. (Measured between
one phase of the U, V, W phase of motor
power line and F.G. )
Please contact the nearest sales
agent if the insulation resistance is
less than 10Ω. Do not perform
measurement or voltage withstand
test against the insulation resistance
of encoder.
Comprehensive
inspection
At least one time every
20000 hours or
every 5 years
-
Please contact the nearest sales
agent.
Component
Expected
life
Notes
Bearing 20000 hours Check whether the sound or vibration is normal due to influence of operation conditions.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keyence SV Series and is the answer not in the manual?

Keyence SV Series Specifications

General IconGeneral
DisplayLCD
Output TypeDigital, Analog
Power Supply24V DC
CommunicationEthernet, RS-232, RS-485
SeriesSV Series
Programming LanguageLadder Logic
MountingPanel mounting
Operating Temperature0 to +50°C
Storage Temperature-20 to +60°C
Vibration Resistance10 to 55 Hz
Shock Resistance30G