2-7
- SV Series User’s Manual -
CONFIGURATION & SPECIFICATIONS
2-3 Servo Amplifier Specifications
This section describes the specifications of the SV series servo amplifier.
General Specifications
Item Specifications
Model
200 V type SV-0052 SV-0102 SV-0202SV-0402 SV-0752
100 V type SV-0051 SV-0101 SV-0201SV-0401-
Capacity 50 W 100 W 200 W 400 W 750 W
Input power supply
Voltage/
frequency
Main
circuit
200 V type
3-phase or single-phase, 200 to 230 VAC, 50/60 Hz 270 to 320 VDC
100 V type
Single-phase, 100 to 115 VAC, 50/60 Hz
Control
circuit
200 V type
Single-phase, 200 to 230 VAC, 50/60 Hz 270 to 320 VDC
100 V type
Single-phase, 100 to 115 VAC, 50/60 Hz
Allowable
voltage
fluctuation
Main
circuit/
Control
circuit
200 V type
170 to 253 VAC
100 V type
85 to 127 VAC
Allowable
frequency
fluctuation
Main circuit/
Control circuit
±5% max.
Allowable
momentary
power failure
Main circuit Full (100% down): 0.5 cycle, Partial (50% down): 1 cycle
Control circuit Approx. 100 ms (200 V), Approx.65ms (100 V)
Overvoltage category III
Control system
3-phase full-wave rectification, IGBT PWM control, sinusoidal current
drive system
Feedback 20-bit serial encoder (incremental/absolute) transmission
Environment
Surrounding Air temperature 0 to +55°C (No freezing)
Storage ambient temperature
-
20 to +70°C(No freezing)
Operating/storage ambient humidity 90% RH max. (No condensation)
Resistance to vibration 4.9 m/s
2
(Complies to JIS C60068-2-6)
Shock resistance 19.6 m/s
2
(Complies to JIS C60068-2-27)
Operating atmosphere
(Enclosure rating, Pollution degree)
Pollution degree: 2 (Inside the industrial control panel with IP54 or higher)
- No corrosive or flammable gas.
- Do not splash water, oil, or chemicals onto the unit.
- No dust in the operation area.
Altitude 1,000 m max. above sea level
Applicable
standards
UL/CSA Standard UL508C, CSA C22.2 No.14
CE Marking
Low-voltage Directive
EN50178
EMI EN55011 Class A, EN61800-3
EMS EN61800-3, EN61000-6-2
North American EMI Regulation FCC Part15 B, ICES-003. Class A
Structure
Installation Base mount
Protection Open, forced cooling
Minimum insulation resistance 1 MΩ min. with 500 VDC megohmmeter
Insulation withstand voltage
1500 VAC min. (between primary side and ground)
1800 VAC min. (between primary side and secondary side)
Weight
Model SV-0052 SV-0102 SV-0202SV-0402 SV-0752
Weight Approx. 0.9kg Approx. 1kg Approx. 1.5kg
Model SV-0051 SV-0101 SV-0201SV-0401-
Weight Approx. 1.1kg Approx. 1.5kg