10-6
ABSOLUTE POSITION SYSTEM
10
- SV Series User’s Manual -
10-3 Installation of Absolute Position System
This chapter introduces parameter setting and ABS encoder setting when absolute position system is used.
Parameter Setting
When absolute position system is used, "*Absolute position system" (SYS_02) is set to "ABS".
Incremental servo motor can not use absolute position system. When increment type servo motor SYS_02
is set to "ABS", "Parameter setting error 0" alarm (040) will occur.
Parameter
type
Category
Level Parameter name Setting range
Setting
unit
Default
Enable
timing
SYS_02 System Basic
* Absolute position
system
0: ABS
1: INC
-1
When power is
ON again