Solo system
solo a and solo b system sections allow solo signals to be selected independently for
each monitor system (A and B). These can be selected as AFL (PFL extinguished), PFL
(PFL illuminated), additive (ADD enabled) or interlock cancelling.
The monitor outputs can be configured for different uses: normal; dual operation; LCR
monitor; broadcast; and user defined. Each of these modes changes the interleaving
logic between differing areas of the monitor output. A mode select button scrolls
through the possible options.
Additionally, there is a solo in place switch for activating the SIP function.