OKI Data Infotech Corporation CONFIDENTIAL
Chapter 5 Troubleshooting (Engine Section and USB Controller Section)
5-77
Service Engineer Inspection
(For inspection criteria, see
Reference to Check/Replace
Parts.)
Reference to
Check/Replace
Parts
Firmware Internal Error
(Mechanical group)
- Install the last firmware version.
- Check that the home position
sensor is correctly installed and
clean.
- Check that the home position
sensor connector is connected
correctly.
- Check that the CARRIAGE
FFC,MW connectors are
connected correctly to both the
HCB1M and the IPB5.
- Check that the ROBOT
CABLE,MW connectors are
connected correctly.
- Firmware version
- Home position sensor
- Robot cable
- FFC
- PCB-ASSY-HCB1M
- PCB-ASSY-IPB5-100
- PCB-ASSY-IPB5-100
Firmware Internal Error (UI
group)
Install the last firmware version.