Field Service Ver. 1.0 Jun. 2008 10. Service Mode
189
Adjustment / Setting
Mode Default value
315
Bit 7654 3210
HEX: 00
State 0000 0000
Bit Setting item
Setting value
Description
01
6-0 Setting printing area for ADF front side poste-
rior end 2 (D).
Set so that the value is the same as that on
mode 314 bit [6-0] or under.
0000000 0 mm
0000001 1 mm
:
1000010 66 mm
others Not available
Mode Default value
316
Bit 7654 3210
HEX: 80
State 1000 0000
Bit Setting item
Setting value
Description
01
7-6 ACS parameter setting for ADF front side
leading edge (2).
00
Parameter for center
(closer to the full color)
01
Parameter 1 closer to
black
10
Parameter 2 closer to
black
11
Parameter 3 closer to
black (closer to black)