10. Service Mode Field Service Ver. 1.0 Jun. 2008
214
Adjustment / Setting
Mode Default value
389
Bit 7654 3210
HEX: 0C
State 0000 1100
Bit Setting item
Setting value
Description
01
5-4 Specify coding format
Selects the coding method for SSL/TLS.
00
3DES_168bits/RC4_128
bits/DES_56 bits or
RC4_40 bits
01
RC4_128 bits/DES_56
bits or RC4_40 bits
10
DES_56 bits or RC4_40
bits
11 Not available
3 Enable Write function
Disable
Enable
Specifies whether to
enable the Write function.
2 Enable Discovery User
Disable
Enable
Specifies whether to
enable Discovery User.
Mode Default value
390
Bit 7654 3210
HEX: A4
State 1010 0100
Bit Setting item
Setting value
Description
01
7-6 Read security level
Selects the security level for Read User
authentication.
00 Not authenticate
01 auth-password
10
auth-password/priv-pass-
word
11 Not available
5-4 Write security level
Selects the security level for Write User
authentication.
00 Not authenticate
01 auth-password
10
auth-password/priv-pass-
word
11 Not available
2 PDF profile reception restriction
Disable Enable
Sets whether to receive
no Profile, or Profile 4 or
later.
1-0 JPEG compression method
00 Standard compression
01 Low compression
10 High compression
11 Not available
d-Color MF201
Service Manual Y109660-1
d-Color MF201