CONFigure:BTOoth Subsystem (BLUETOOTH, K8) R&S FSL
1300.2519.12 6.364 E-11
C
ONFigure:BTOoth:RTPower:DAVerage:STARt
This command sets the start time for the power measurement of the DPSK sections of the
packet.
Note: This command is only available with active Relative Transmit Power measurement (see
CONFigure:BTOoth:MEASurement command).
Parameter
0 to 100%
Example
CONF:BTO:RTP:DAV:STAR 20
Sets the start time for the power measurement of the DPSK sections of the packet.
Characteristics
RST value: 10%
SCPI: device–specific
Mode
BT
CONFigure:BTOoth:RTPower:DAVerage:STOP
This command sets the stop time for the power measurement of the DPSK sections of the
packet.
Note: This command is only available with active Relative Transmit Power measurement (see
CONFigure:BTOoth:MEASurement command).
Parameter
0 to 100%
Example
CONF:BTO:RTP:DAV:STOP 80
Sets the stop time for the power measurement of the DPSK sections of the packet.
Characteristics
RST value: 90%
SCPI: device–specific
Mode
BT
CONFigure:BTOoth:RTPower:GAVerage:STARt
This command sets the start time for the power measurement of the GFSK sections of the
packet.
Note: This command is only available with active Relative Transmit Power measurement (see
CONFigure:BTOoth:MEASurement command).
Parameter
0 to 100%
Example
CONF:BTO:RTP:GAV:STAR 20
Sets the start time for the power measurement of the GFSK sections of the packet.