Remote Commands of the 1xEV-DO BTS Analyzer Option (K84) R&S FSL
1300.2519.12 6.636 E-11
CALCulate:LIMit:ESPectrum Subsystem (EVDO, K84)
The CALCulate:LIMit:ESPectrum subsystem defines the limit check for thr Spectrum Emission Mask.
Commands of the CALCulate:LIMit:ESPectrum Subsystem
CALCulate<1|2>:LIMit<1...8>:ESPectrum:MODE
CALCulate<1|2>:LIMit<1...8>:ESPectrum:RESTore
CALCulate<1|2>:LIMit<1...8>:ESPectrum:VALue
CALCulate<1|2>:LIMit<1...8>:ESPectrum:MODE
This command activates or deactivates the automatic selection of the limit line in the Spectrum
Emission Mask measurement.The numeric suffix at CALCulate<1|2> specifies the
measurement window. The numeric suffix at LIMit<1...8> is irrelevant for this command.
Parameter
AUTO The limit line depends on the measured channel power.
MANUAL One of the three specified limit lines is set. The selection is made with the
CALCulate<1|2>:LIMit<1...8>:ESPectrum:VALue command.
Example
CONF:CDP:MEAS ESP
Selects Spectrum Emission Mask measurement.
CALC:LIM:ESP:MODE AUTO
Activates automatic selection of the limit line.
Characteristics
RST value: AUTO
SCPI: device-specific
Mode
EVDO
CALCulate<1|2>:LIMit<1...8>:ESPectrum:RESTore
This command restores the predefined limit lines for the Spectrum Emission Mask
measurement. All modifications made to the predefined limit lines are lost and the factory–set
values are restored.
The numeric suffix at CALCulate<1|2> specifies the measurement window. The numeric suffix
at LIMit<1...8> is irrelevant for this command.
This command is an event and therefore has no *RST value and no query.
Example
CALC:LIM:ESP:REST
Resets the limit lines for the Spectrum Emission Mask to the default setting.
Characteristics
RST value: -
SCPI: device-specific
Mode
EVDO