R&S FSL SENSe Subsystem (EVDO, K84)
1300.2519.12 6.663 E-11
Example
CDP:SLOT 2
Selects power control group 2.
Characteristics
RST value: 0
SCPI: device-specific
Mode
EVDO
[SENSe<1|2>:]CDPower:TPMeas
This command actives or deactivates the timing and phase offset evaluation of the channels to
the pilot. If the value is OFF or if more than 50 channels are active, the command TRACe? and
CALCulate<1|2>:MARKer<1...4>:FUNCtion:CDPower[:BTS]:RESult? returns a value
of '9' for the timing and phase offset as the result. If the value is ON, the timing and phase
offsets are calculated and returned.
The numeric suffix at SENSe<1|2> is irrelevant for this command.
The results are queried using theTRACe<1|2>[:DATA]command and the
CALCulate<1|2>:MARKer<1...4>:FUNCtion:CDPower[:BTS]:RESult? command.
Parameter
ON | OFF
Example
CDP:TPM ON
Activate timing and phase offset.
Characteristics
RST value: OFF
SCPI: device-specific
Mode
EVDO