R&S FSL 1xEV-DO BTS Analyzer (Option K84)
1300.2519.12 4.373 E-11
New
Creates a new channel table name that can be seen in the dialog box from then on. The name
will be automatically set to 'ChannelTable'. By default, the resulting channel table is completely
empty (i.e. it contains no channel at all).
The submenu contains the following items:
Add Channel
Delete Channel
Meas
Sort
Save
Cancel
Reload
Remote: CONF:CDP:CTAB:NAME "NEW_TAB"
Add Channel
Inserts a new channel below the one selected. The default values for a new channel are:
ChannelType MAC
Walsh Ch.SF 2.64
SymbolRate 19.2 ksps (automatically calculated)
Modulation BPSK-I
Power 0 dB (automatically calculated)
State Off
DomainConflict No (automatically calculated)
To change the channel type use the dropdown menu that opens when selecting / highlighting
the Channel Type field that should be changed and pressing the ENTER key. The radio
configuration settings are changed in the same way.
To change the channel number type another channel number in the form
'ChannelNumber.SpreadingFactor' or simply the code number (see Select Code Slot for
details) in the respective field and confirm the change with the ENTER key.
To activate or deactivate a channel, simply select the field and confirm with the ENTER key.
The R&S FSL automatically checks for conflicts between two active channels.
Remote: CONF:CDP:CTAB:DATA "0…13, 2…7, 0…127, 0…30, 0, 0, 0 | 1"
Delete Channel
Deletes the selected channel without further notice.