Edge: The operator can select if the output signal is a positive (reference on
the rising edge) or a negative (reference on the falling edge) pulse.
Pulse Width: Configures the Pulse Width of the 1PPS output. The Pulse
Width is entered and displayed in nanoseconds (ns). The default Pulse
Width is 200 milliseconds.
PPS Output: Status Window
To view the current settings of the 1PPS output, go to its Status window. For
instructions, see: "Viewing Input/Output Configuration Settings" on page363.
The Web UI list entries for these cards are: 1PPS/Frequency BNC and 1PPS/Fre-
quency RS-485.
The connector number is: J3 (BNC card); J1 (RS-485 card).
The Status window displays the following settings:
Signature Control: Displays the current configuration of Signature Control.
See also: "Signature Control" on page183.
Frequency: Indicates the configured frequency of the 1PPS output signal.
Offset: Displays the configured Offset (to account for cable delays or other
latencies).
Edge: Shows if the on-time point of the 1PPS output is the rising or falling
edge of the pulse.
Pulse Width: Displays the configured Pulse Width of the 1PPS output. The
Pulse Width is displayed in nanoseconds (ns). The default Pulse Width is
200 milliseconds.