8.3.5 Technical data
8.3.5.1 Single Motor Modules
Technical data
Table 8-6 Single Motor Modules D type (3A to 30A, 30A(slim))
Feature Unit Article No. 6SL5120-
1UE13-
0AD0
1UE15-
0AD0
1UE21-
0AD0
1UE21-
8AD0
1UE22-
4AD0
1UE23-
0AD0
1UE23-0
SD0
Output data
Rated current (l
rated
)
Intermittent duty current (l
s6
) 40%
Peak current (l
max
)
A
A
A
3
4
9
5
6.7
15
9
12
27
18
24
54
24
32
72
30
40
90
30
40
90
Output voltage3AC V 0 … 0.707 x DC link voltage
1)
(0 ... 480V at 680VDC)
Output frequency Hz 0 ... 550
2)
Apparent power for U
DC
of 600V
Rated power IEC
3)
Rated power NEC
4)
kVA
kW
hp
2.2
1.1
1.5
3.7
2.2
3.0
6.6
4.0
5.0
13.2
7.5
10
17.6
11
15
22
15
20
22
15
20
Input data
DC link voltage (U
DC
)
Overvoltage trip
Undervoltage trip
5)
Electronics power supply
V
V
V
V
495 … 720
820
380 … 432
24
DC link current (I
DC link
) A 3.7 6.2 11.2 22.5 30 37 37
DC link capacitance μF 110 110 110 220 390 705 705
Current-carrying capacity
DC link busbars
24 V DC busbars
A
A
100
6)
20
200
20
100
6)
20
Current consumption of the electronics
at 24VDC
A
0.7
0.75
0.8
1
1
0.75
1.2
Power loss W 29 40 65 150 189 261 272
Cooling air requirement m
3
/h 18 20 22 33 33 58 33
Weight kg 4.6 4.6 4.6 4.6 4.7 7.9 4.6
Cable lengths m See Chapter "Maximum permissible cable lengths (Page54)"
1)
In the case of overmodulation, a motor output voltage up to 3% higher is possible.
2)
Higher output frequencies up to a maximum of 3200Hz are possible with an additional license.
3)
Rated power of a typical standard induction motor at 3 AC 400V according to IEC 60947-4-1:2018 Annex G Table G.1
4)
Rated power of a standard induction motor at 3 AC 460 V according to NEC Table 430.250
5)
Depends on the parameterized device supply voltage
6)
200 A when using 6mm DC link bridges (Article No. 6SL3162-2BB00-0AA0)
Motor Modules
8.3Motor Modules 3 ... 30 A and 2x3 ... 2x18 A
Booksize power units
Equipment Manual, 09/2023, A5E53307519B AA 163