8.3.5.2 Double Motor Modules
Technical data
Table 8-8 Double Motor Modules D type (2x3A to 2x18A, 2x18A(slim))
Feature Unit Article No. 6SL5120-
2UE13-0A
D0
2UE15-0A
D0
2UE21-0A
D0
2UE21-8A
D0
2UE21-8SD
0
Output data
Rated current (l
rated
)
Intermittent duty current (l
s6
) 40%
Peak current (l
max
)
A
A
A
2 x 3
2 x 4
2 x 9
2 x 5
2 x 6.7
2 x 15
2 x 9
2 x 12
2 x 27
2 x 18
2 x 24
2 x 54
2 x 18
2 x 24
2 x 54
Output voltage3AC V 0 … 0.707 x DC link voltage
1)
(0 ... 480V at 680VDC)
Output frequency Hz 0 ... 550
2)
Apparent power for U
DC
of 600V
Rated power IEC
3)
Rated power NEC
4)
kVA
kW
hp
2 x 2.2
2 x 1.1
2 x 1.5
2 x 3.7
2 x 2.2
2 x 3.0
2 x 6.6
2 x 4.0
2 x 5.0
2 x 13.2
2 x 7.5
2 x 10
2 x 13.2
2 x 7.5
2 x 10
Input data
DC link voltage (U
DC
)
Overvoltage trip
Undervoltage trip
5)
Electronics power supply
V
V
V
V
495 … 720
820
380 … 432
24
DC link current (I
DC link
) A 7.5 12.5 22.5 45 45
DC link capacitance μF 235 235 235 705 705
Current-carrying capacity
DC link busbars
24 V DC busbars
A
A
100
6)
20
200
20
100
6)
20
Current consumption of the electronics
at 24VDC
A
1
1.1
1.1
0.95
1.3
Power loss W 59 88 159 282 291
Cooling air requirement m
3
/h 22 25 27 62 33
Weight kg 4.7 4.7 4.7 8.1 5.1
Cable lengths m See Chapter "Maximum permissible cable lengths (Page54)"
1)
In the case of overmodulation, a motor output voltage up to 3% higher is possible.
2)
Higher output frequencies up to a maximum of 3200Hz are possible with an additional license.
3)
Rated power of a typical standard induction motor at 3 AC 400V according to IEC 60947-4-1:2018 Annex G Table G.1
4)
Rated power of a standard induction motor at 3 AC 460 V according to NEC Table 430.250
5)
Depends on the parameterized device supply voltage
6)
200 A when using 6mm DC link bridges (Article No. 6SL3162-2BB00-0AA0)
Motor Modules
8.3Motor Modules 3 ... 30 A and 2x3 ... 2x18 A
Booksize power units
Equipment Manual, 09/2023, A5E53307519B AA 165