Proceed as follows to connect the cores in the connection plug:
1. Starting with W2, V2, U2, insert the cores into the open terminals.
The cores must be inserted as far as they will go.
For larger cross-sections, it is helpful if W2, V2, U2 are simultaneously inserted and
secured by screws.
2. Tighten the screws. Slotted screwdriver 0.8 x 4.0mm. Tightening torque: 0.5 - 0.6Nm
(4.4lbf in)
8.3.10.5 Wiring the connection plug with push-in connection
Requirement
WARNING
Electric shock or 󹪝re caused by non-certi󹪝ed plug connection plug in the power circuit
Using a non-certi󹪝ed connection plug can result in overheating, 󹪝re and/or electric shock.
Only use certi󹪝ed connection plugs.
Required tools:
Slotted screwdriver 0.8 x 4.0mm
Procedure
Table 8-17 Connection plug with push-in connection
6SL3162-2MB00-0AC0 Terminal Designation Technical data
BR+ Holding brake connec‐
tion
Spring-loaded terminal with ac‐
tuator
BR-
Motor PE/ground con‐
nection
U2 Motor connection
V2
W2
Motor Modules
8.3Motor Modules 3 ... 30 A and 2x3 ... 2x18 A
Booksize power units
Equipment Manual, 09/2023, A5E53307519B AA 181