Loading...
4-26
Group 02: IM Motor Parameters
Code Parameter Name Setting Range Default Unit
Control mode
Attribute
V/F
V/F
+PG
SLV SV
PM
SV
PM
SLV
SLV2
690V: 504~720 -
02-20
No-Load Current
of Motor 2
0.01~600.00 - A O X X X X X X
02-21
Rated Current of
Motor 2
10%~200% of inverter’s
rated current
- A O X X X X X X
02-22
Rated Rotation
Speed of Motor 2
0~60000 - Rpm O X X X X X X
02-23
Rated Voltage of
Motor 2
200V: 50.0~240.0 220.0
V O X X X X X X
400V: 100.0~480.0 440.0
575V: 150.0~670.0 575.0
690V: 200.0~804.0 690.0
02-24
Rated Power of
Motor 2
0.01~600.00 - kW O X X X X X X
02-25
Rated Frequency
of Motor 2
5.0~599.0 60.0 Hz O X X X X X X
02-26 Poles of Motor 2 2~16 (Even) 4 - O X X X X X X
02-27
~
02-31
Reserved
02-32
Resistance
between Wires of
Motor 2
0.001~60.000 - O X X X X X X
02-33
Proportion of
Motor Leakage
Inductance
0.1~15.0 3.4 % X X O O X X X
02-34
Motor Slip
Frequency
0.10~20.00 1.00 Hz X X O O X X X
02-35
~
02-36
Reserved
02-37
Motor Mechanical
Loss
0.0~10.0 4.0 % X X X O O X X

Table of Contents