4-58
Group 12: Monitoring Parameters
Code Parameter Name Setting Range Default Unit
Control mode
Attribute
V/F
V/F
+PG
SLV SV
PM
SV
PM
SLV
SLV2
12-11
Output Current of
Current Fault
Display the output current
of current fault
- A O O O O O O O
12-12
Output Voltage of
Current Fault
Display the output voltage
of current fault
- V O O O O O O O
12-13
Output Frequency
of Current Fault
Display the output
frequency of current fault
- Hz O O O O O O O
12-14
DC Voltage of
Current Fault
Display the DC voltage of
current fault
- V O O O O O O O
12-15
Frequency
Command of
Current Fault
Display the frequency
command of current fault
- Hz O O O O O O O
12-16
Frequency
Command
If LED enters this
parameter, it only allows
monitoring frequency
command.
- Hz O O O O O O O
12-17
Output Frequency
Display the current output
frequency
- Hz O O O O O O O
12-18
Output Current
Display the current output
current
- A O O O O O O O
12-19
Output Voltage
Display the current output
voltage
- V O O O O O O O
12-20
DC Voltage (Vdc)
Display the current DC
voltage
- V O O O O O O O
12-21
Output Power (kw)
Display the current output
power
- kW O O O O O O O
12-22
Motor’s Rotation
Speed (rpm)
Display motor’s current
rotation speed
in VF/SLV mode
Motor’s rotation speed =
output power
x(120/motor’s pole
number)
In PG/SV mode, motor’s
rotation speed is
calculated by feedback
frequency.
Max limit is 65535
- rpm O O O O O O O
12-23
Output Power
Factor (Pfo)
Display the current output
power factor
- - O O O O O O O
12-24 Control Mode
Display control mode
0: VF
1: PG
2: SLV
3: SV
4: PSV
5: PMSLV
6: SLV2
- - O O O O O O O
12-25
AI1 Input
Display the current Al1
input
(-10V corresponds to
-100%, 10V corresponds
to 100%,)
- % O O O O O O O