2
21 PID integral reset PID I-Reset
ON: PID integral value reset
O O O O O O O
22 Reserved Reserved
Reserved
- - - - - - -
23 Reserved Reserved
Reserved
- - - - - - -
24 PLC input PLC Input
ON: Digital PLC input
O O O O O O O
25 External fault Ext. Fault ON: External fault alarm O O O O O O O
26
3-Wire sequence
(Forward/Reverse
command)
3-Wire
(FWD/REV)
3-wire control (forward/reverse
command). ON: Reverse; OFF:
Forward.
When the parameter is set to 26,
terminal S1 and terminal will
become operation command and
stop command respectively, and
their original functions will be
closed.
O O O O O O O
27
Local/Remote
selection
Local/Remote
ON: Local mode (via the digital
operator)
OFF: Frequency command and
operation command will be
determined according to
the setting of parameter
(00-02 and 00-05).
O O O O O O O
28
Remote mode
selection
Remote Mode
Sel
ON: RS-485 communication
OFF: Control circuit terminal
O O O O O O O
29
Jog frequency
Selection
JOG Freq sel
ON: Select jog frequency
command
O O O O O O O
30
Acceleration/decel
eration time
selection 2
Acc/Decel Time
Selection 2
Acceleration/ deceleration time
selection command 2
O O O O O O O
31
Inverter
overheating
warning
Overheat Alarm
ON: Inverter overheat alarm
(OH2) input ( will display
OH2)
O O O O O O O
32 Sync command Sync Command
ON: Synchronous speed start
OFF: Synchronous speed close
(Start other frequency
command).
O O O O O O O
33 DC braking
DC Brake
Command
ON: Perform DC braking
O O O O X X O
34
Speed Search 2
(from the frequency
command)
Speed Search 2
ON: Search speed from set
frequency
O O O O X O O
35 Time function input Time Input
.Set the time function at 03-33,
03-34
.Set the time function output at
03-11, 03-12
O O O O O O O
36
PID Soft start
ineffective
PID SFS Disable
ON: PID slow-start off
O O O O O O O
37
Traversing
operation
Wobble Run
ON: Frequency wobbling
operation
O O X X X X O
38
Upper Deviation of
traverse operation
Upper Dev Run
ON: Upper offset off frequency
wobbling
O O X X X X O