4-185
Example: Acceleration / deceleration timing when 05-00 is set to 1. In this example the following parameters are
set:
00-02=1
(External Terminal Operation)
03-00=0 (Terminal S1: Forward /Stop)
03-01=1 (Terminal S2: Reversal /Stop)
03-02=2 (Terminal S3: Speed 1)
03-03=3 (Terminal S4: Speed 2)
03-03=4 (Terminal S5: Speed 3)
*Speed 1 is required to confirm if AI2 function setting (04-05) is set to 0 (Auxiliary frequency). If 04-05=0, it will
make the frequency of speed 1 set to AI2 auxiliary frequency and the value is determined by AI2. If function of
speed 1 is generally used, set AI2 to other functions except 0 (the recommended value: set 10 ADD to AI1.)
Acceleration / Deceleration Calculation Mode 1:
If the run command is cycled on and off, acceleration and deceleration time (a ~ f) is calculated based on the
active speed command as follows:
Te rminal S1
Te rminal S2
Te rminal S3
Te rminal S4
Run Run RunStop Stop Stop
Off
OffOff
Off
On
On
abcdef
Speed
Command 0
Speed
Command 1
Speed
Command 2
05-01
05-02
05-03
T
Hz
in sec.
(05-17) x (05-01) (05-18) x (05-01) (05-19) x (05-02)
(01-02) (01-02) (01-02)
a = b = c =
(05-20) x (05-02) (05-21) x (05-03) (05-22) x (05-03)
(01-02) (01-02) (01-02)
d = e = f = in sec.