VA Motion Controller Programming Manual
515
displacement (pulse) 8000 (11000-3000), DI_Rest_Len_Min ~ DI_Rest_Len_Max within the set
range, so again when DI0 to FALSE, the operation of Count_out cleared.
Case 2:When counter_enable FALSE to TRUE grounds, and maintained. di_start_Valid
becomes TRUE when the external signal DI3 signal is valid, the counter 3 starts counting the
number of high, Count_out display the current pulse, when the designated DI0 di_reset_no from
FALSE to TRUE again until DI0 becomes FALSE, the controlled axis through this period
displacement (pulse) 4000 (19000-15000), is not within DI_Rest_Len_Min ~ DI_Rest_Len_Max
set interval, and therefore becomes FALSE when DI0 again, will not be cleared Count_out
operation.
Demonstration program Ⅳ
Example: loop count mode pulse number counter shaft axif_counter
1, variables, and procedures