VA Motion Controller Programming Manual
599
3.1.2. NS_CC_CANopen_NMT_Write(Network state write
command)
FB / FC
Explanation
Applicable model
FB
This instruction is used to write the current
status of network devices in which the respective
network node in the network
Input parameters
name
Features
type of data
Range
setting (default
value)
The
timing of the
entry into force
AXIF_no
(node
number)
To control
node setting
instruction
WORD
1 to 16, 18
Excute to
TRUE
Excute
(execute bit)
When
Excute is True,
the instruction
is executed
BOOL
TRUE or
FALSE (FALSE)
NMT_Start_
Node (start node)
This
parameter is
TRUE, start the
network node
BOOL
TRUE or
FALSE (FALSE)
NMT_Stop_
Node (stop node)
This
parameter is
TRUE, the
network node is
stopped
BOOL
TRUE or
FALSE (FALSE)
NMT_Enter_
Preoperational (pre
This
parameter is
BOOL
TRUE or
FALSE (FALSE)