VA Motion Controller Programming Manual
620
2. A timing diagram
When the above, the servo parameter assignment Vector P03.19 (position error value is too
large), the corresponding index: 2000 + # 16 # 16 16 # 3 = 2004, corresponding to the sub-index
19 16 # 13, a length of 4 bytes , the current No. 1 trigger module assignment node position is too
large value.