5. Installation
Image 5-67
SNMP conguration
Management System address to receive traps, add address
1.TiponAdd
The IP address input window opens.
2. Enter the IP address of the management server.
3. Tip on OK to activate.
The new server is added to the list of management servers.
Trap resend interval
Time between two traps to be send to the management servers. This time is set in minutes and can be
different for Non critical trap and Critical traps.
To change the time, tip on the up down control of the spin box of the corresponding trap type until the
desired interval is reached.
Trap type
SNMP exists in different versions. You have SNMP V1 and SNMP V2. The difference is basically the
format of the SNMP messages. Some management systems will support V1, others will support V2.
Depending on the management system used one should select V1 or V2 traps to be sent out to the man-
agement system.
To change the trap type, tip on the combo box next to Trap type and select the corresponding type.
R59770488 COMMUNICATOR TOUCH PANEL 06/06/2012