2. Controls
Current light output is only indicated when a CLO key is installed.
Lamp power
A histogram indicates the current value of the lamp power. The diagram indicates also the minimum and
maximum limits for the lamp currently in use.
The color of that histogram changes from green when lamp power is minimum to red when lamp power
is maximum.
Lamp information
The following information is given in a read only format:
• Run time: the time the lamp is used since it first start up.
• Remaining run time: remaining run time that the lamp can be used without risk of damaging the pro-
jector.
2.3.3 Light output mode
2.3.3.1 Target set up for Normal mode
Mode selection must be done in Installation → Lamp.
How to setup
1. Adjust with the slide bar until the desired lamp power is obtained. (image 2-18)
Or,
click on the up down control of the spin box until the desired value is reached
Or,
click inside the text box and enter a new value with the keyboard.
The Current lamp output and Lamp power will change accordingly.
Image 2-18
Normal lamp output mode
2.3.3.2 Target set up for CLO mode
Mode selection must be done in Installation → Lamp → Light output.
R59770488 COMMUNICATOR TOUCH PANEL 06/06/2012 25