148Service Manual – CS7010™ 28 - Engine System - LPG LEV
Checking LPG Primary Pressure
1. Turn off the propane tank valve with the engine running
and allow the engine to run out of fuel.
2. Turn key switch off.
3. Swing out the propane tank.
4. Remove the steel plate.
5. Remove the primary chamber test port plug located on top of the vaporizer regulator and install the test
tting.
6. Install tting from LPG pressure test kit into the thread
adapter.
7. Using the LPG test gauge kit - Part # 56504450, hook up
the blue pressure gauge hose to the tting.
8. Open propane tank valve.
9. Start engine. (Specication - 4.3 PSI, 32.7kPA)
10. When nished, reinstall the test port plug using a suitable
pipe thread sealant. (E.G. Loctite 30534)
Remove Steel
Plate