115Service Manual – CS7010™ 24 - Electrical System
Maintenance and Adjustments
Charging the Battery (Battery Model)
See User Manual
Generator Drive Belt
The generator drive belt tension is maintained by an auto-tensioner and does not require adjustment.
Troubleshooting
Alternator-generator is not charging
Potential Causes
Broken or slipping drive belt - Check the drive belt
No power to voltage regulator terminal - Check for battery voltage (36v) to the voltage regulator connector
Open or corroded cable connections - visually inspect cable connections
Generator/Regulator assembly
Insufcient machine operation time (Battery Model)
Potential Causes
Battery is not fully charged
Loose or corroded cable connections
Battery
Insufcient machine operation time with engine off (Hybrid models)
Note: Hybrid machines are not normally intended to be operated without the engine running.
Potential Causes
Battery is not fully charged
Loose or corroded cable connections
Battery